v50l pnlite connection and shortcut problem

  • This topic is empty.
Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #896
    Avatarmelonenbrause
    Member
    • Total Post: 2
    • Newbie
    • β˜…

    hi everybody,
    i have a problem with wyse v50l thin client.
    i use the pnlite with published apps.

    my problem:
    the shortcuts of the pub apps have not the icon of the app but the default, custom ica connection icon (white background with red “ball” in it).
    how do i get the wanted desktop shortcuts? any idea?

    my second problem ist that every app i start starts a new session. all apps got the same configuration on the ps4.5.
    also, any idea?

    i hope you understand what my problems are and what i try to say … πŸ˜‰

    thx for help.

    regards,
    melone

    #11532
    ConfGenConfGen
    Keymaster
    • Total Post: 11109
    • Jedi Master
    • β˜…β˜…β˜…β˜…β˜…β˜…β˜…

    Look like your ICA configuration on the Linux box is wrong.
    Try not using MFServer but PNLiteServer.
    This should help.

    CG

    #11545
    Avatarmelonenbrause
    Member
    • Total Post: 2
    • Newbie
    • β˜…

    hi confgen,
    thx for your answer.

    actually i configure the tc with the wlx.ini file where i give them the pnliteserver.

    BUT now i deleted the entry “pnliteserver” and used “mpserver” and everything ist working fine!!!

    but i am wonderin why? because i thought i have to use the pnlite server to user the pnagent …. strange πŸ™„

    but thx anyway, with your post i tried the setting πŸ˜€

    regards,
    melone

    #12654
    Avataranjoha
    Member
    • Total Post: 6
    • Newbie
    • β˜…

    I also have a issue regarding PNlite and MPserver on Wyse Linux.
    My enviromet is to citrix farms, one web interface server with PNA configured. When I use PNlite server on Thin OS wyse’s, everything works fine. But when using the same configuration on Wyse Linux we have several problems. Icons apper as Citrix icons, and Seamless not working. When using MPserver thing begins to work but when using MPServer it can’t read information from both farms. It reads only settings from the first MPServer.

    Sombody have the same issue and maybe a solution.

    We are using Wyse S50 and V50 with FW 6.4 and we have tried ICA 9.3 and ICA 10.1 client on the wyse. Same problems.

Viewing 4 posts - 1 through 4 (of 4 total)