We upgraded to firmware 1.5. There’s an option in there to “Shutdown the System Automatically” and we wanted to configure that in the Xen.ini file but can’t find the parameters. Via the GUI it’s located under RemoteConnections>GeneralOptions
shutdown=yes
Try
AutoSignoff=yes Shutdown=yes
CG
How about the Shutdown Counter? By default it is set to 10 seconds. Is there a xen.ini configuration that can change that?
I tried Shutdowncounter=1 and Shutdown=1 and those don’t seem to work.
AutoSignoff=yes Shutdown=yes
Shutdowncounter=x (where x can be 0-60 with 0=immediately)
should work as it is a default WTOS parameter. I doubt they have disabled it in Xenith.
CG
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |