We’ve got our S10’s pointing at the PNAgent service on a couple of our servers, using the usual ‘PnlinteServer=xx.xx.xx.xx:8080’ line in our wnos.ini.
However, after applying ‘rollup 04’ to our servers, the S10 fail to communicate with the PNA, giving a ‘-1’ error. Uninstalling R04 fixes the problem. We’re on v5.3.015, anyone seen this behaviour or know how to fix it?
TIA.
You can fix this two ways.
1 way is to upgrade the FW on S10 to minimum 6.1. If you have any 1200le this is not the solution because 1200Le doesn’t have this FW.
The other way is change C:Program FilesCitrixSystem32ctxxmlss.exe to a exe file from RP3 and it will work againg.
Best regards AJ
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |