April 1, 2008 at 9:03 pm #1088
hi anybody can help me.
I am a new guy, I tell you first.
when i reload s10 unit ,one failuie message alway come out “failuie client and archi………………..” so please help me how to do this one, thx ❓April 1, 2008 at 9:29 pm #12423841786-01r 991474-01
April 2, 2008 at 1:49 am #12429Hi,
Can you tell me, does the unit boot without the trying to upload an image? What version of firmware are you trying to load?
Cheers,
-TTApril 2, 2008 at 3:06 am #12434Can you tell me, does the unit boot without the trying to upload an image? What version of firmware are you trying to load?
I have tried all of these but still fail:
2.1
5.1.028_32
6.10At the begining of pxe, everything is fine. But it will stop with a message “Failure_Client_check…….”
By the way ,i already include the push.k into the folder.
Pls help me.thx
April 2, 2008 at 5:49 am #12435There is no 2.1 image for WTOS.
What tools do you use to reflash? What is the complete name of one of the image files? Does the unit boot without flashing? Why do you use PXE to reflash and not FTP?
Please give us more information. Without we cannot help you at all.CG
April 3, 2008 at 12:41 am #12451There is no 2.1 image for WTOS.
What tools do you use to reflash? What is the complete name of one of the image files? Does the unit boot without flashing? Why do you use PXE to reflash and not FTP?
Please give us more information. Without we cannot help you at all.CG
_________________
Try the free Configuration Generator to generate your ini files for WTOS and Linux and create CE addon packages *** Don’t forget PayPal if you like it ***
I use wyse siple imager doing pxe.
the image name are
6.1int_31.572_1s10-6.1.0_08-32.i2d
6.1i0_31.572m_1s10-6.1.0_07-32.i2d
5.1.028_32
2.1_32
this unit not boot without flash, it is the old one “991474 841786-01r”thx again,
April 3, 2008 at 6:20 am #12454It looks like you have a non-RoHS compliant unit. These old unit only had 2MB of flash and therefore an 32MB image will not fit.
What is the part number of the S10?
CG
April 6, 2008 at 9:27 pm #12514Thanks for replying. I just wondering when doing imaging, does it check for the right hardware, eg: if I have an 64mb flash, can it load with the 32mb image ? ie: is it an upward compatible, a bigger capacity flash to load with smaller image, will it work ? if not , is there any other way to skip the checking ?
The S10 logic board part number is 841786-01R
April 7, 2008 at 5:58 am #12519Normally smaller images will be loaded in bigger flash but, of course, not the other way round.
The only checking that is done is regarding the OS and unit type, so that you do not load a WTOS image on a CE box, etc…I was not asking for the part number of the logic board but the part number of the unit itself. This can be found outside on the unit on the small label.
CG
April 7, 2008 at 9:56 pm #12541unfortunately, customer alway send us the logic board only, so we have not got the unit sn.
but i think the s10 unit has three parts only. mem flash and l/b.and we already found lots of this sorts of problem. pls help us.
thx
April 8, 2008 at 6:10 am #12546Have you tried a 2MB i2d file? This should work.
Just as I am curious: Why do customers send you LB?CG
April 8, 2008 at 10:04 pm #12560
Have you tried a 2MB i2d file? This should work.
Just as I am curious: Why do customers send you LB?thx again,
but i dont know where can I find the 2MB i2d file(I already checked the firmware database).
by the way ,our customers are not end-user.April 9, 2008 at 1:41 am #12561the failure message
FAILURE-CLIENT-AND-TYPE-CHECKEvan I use the brand new L/B(841786-01R) doing the PXE, still got this sort of meesage.
Pls help us , master
April 9, 2008 at 7:00 am #12564April 9, 2008 at 10:31 pm #12589the failure message
FAILURE-CLIENT-AND-ARCHIVE_TYPE-CHECK
STILL NOT WORKING
-