  • #105311
    nstaab
    Participant
    • Total Post: 46
    • Frequent Flyer
    • ★★★

    Anyone have any idea what the heck the PW requirements are for Wyse Converter? I’ve tried all sorts of combinations, but I get the attached error every single time.Converter error

    #105334
    ConfGen
    Keymaster
    • Total Post: 10696
    • Jedi Master
    • ★★★★★★★

    I think to remember it has to be at minimum 8 characters, upper and lower case, number, and a special character (but not one of the listed ones \/’`,~:;*?”&^)
    Try “Wyse#123” if that works.

    CG

    #105343
    nstaab
    Participant
    • Total Post: 46
    • Frequent Flyer
    • ★★★

    No luck. I believe the issue is that Wyse Converter follows the minimum domain PW requirements – which is fine, except my domain requires 20+ character PWs but Wyse does not work with PWs that long.

    #106265
    Diginerd
    Keymaster
    • Total Post: 53
    • Back Stage Pass
    • ★★★★

    Are your device in the domain?