I sometimes have issues with our wireless 3125se thin clients connecting to our AS400. usually when they are started up in the mornings.
it only happens on the wireless ones, the wired ones work just fine, so we are guessing that the 400 session may be attempting to start while the NIC may still be negotiating for an IP address.
is there an auto-reconnect feature in the system?
if we could set the AS400 session to auto-reconnect I would think that would take care of the issue.
You can configure a reconnect in the Connection settings.
On the 5th config tab you will find the option to reconnect when host is closed. This should help you.
CG
Cookie | Duration | Description |
---|---|---|
cookielawinfo-checkbox-analytics | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics". |
cookielawinfo-checkbox-functional | 11 months | The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional". |
cookielawinfo-checkbox-necessary | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary". |
cookielawinfo-checkbox-others | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other. |
cookielawinfo-checkbox-performance | 11 months | This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance". |
viewed_cookie_policy | 11 months | The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data. |