Get Device Config WDM 4.5.3

  • This topic is empty.
Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #1459
    AvatarRWP
    Member
    • Total Post: 1
    • Newbie

    Can not update a factory default unit using Package Mgr.

    1. Configured a v30 with 2 ica connections and security.
    2. In WDM, right clicked the configured unit and selected “Get Device Configuration”
    3. Named it, used Replace.
    4. In WDM, dragged new config file onto Device Mgr and selected factory default unit.
    5. Admin screen appears on unit, it then reboots
    6. Unit comes back online, but still has factory default settings.

    Note: I upgraded unit to FR2 Hot Fix 22 (Build 581) using FTP upgrade method.

    Any help would be great! Thanks RWP

    #13927
    Avatarkaraziel
    Member
    • Total Post: 74
    • Back Stage Pass
    • ★★★★

    Contact Wyse Tech Support and ask for updated RegFilter40.tpl. Could be issue with desired settings being filtered out by default.