Reply To: WYSE S10 – Autoconnect to Published Desktop WTOS 6.5

#24171
Avatarrobadob5266
Member
  • Total Post: 1
  • Newbie
  • ★

I’ve recently built a new Citrix XenApp 6.5 farm to replace our now aging Presentation Server 4.5 farm.

We have been successfully using Wyse S10 thin clients for a number of years without an issue.

However, I simply cannot get the S10 to connect to the Web Interface server in our new XA 65 environment?

It will connect to the XML service on the Session Controller XA server, but not the XenApp Services site on our WI server?

Our S10’s are running WTOS 7.1.207.

The wnos.ini file generated using ConfGen is below:
;*************************************************************
;* *
;* This wnos.ini file was generated with the *
;* Configuration File Generator 6.4.010 *
;* Copyright by Thomas Moellerbernd *
;* *
;* http://www.technicalhelp.de *
;* *
;*************************************************************

;*************************************************************
;* General 1 *
;*************************************************************

Autoload=2
#Privilege=Low Lockdown=No

;*************************************************************
;* Peripherals *
;*************************************************************

Language=AU

;*************************************************************
;* Display *
;*************************************************************

; If you are using a version of WTOS code < 7.0.1_13 please use:
; Resolution=1280×1024 Refresh=
Screen=1 Resolution=1280×1024
DeskColor=”37 176 64″
DesktopColorDepth=32
Desktop=FinsburyLogo.bmp Layout=Center
Screensaver=”10″ LockTerminal=no Type=0 Image=FinsburyLogo.bmp

;*************************************************************
;* Time *
;*************************************************************

Timeserver=dc3.gotham.local
TimeZone=’GMT + 09:30′ ManualOverride=yes

;*************************************************************
;* Network *
;*************************************************************

SignOn=No
MaxVNCD=1
VncPassword=”F1nsbury”
VncPrompt=No
EnableLocal=Yes

;*************************************************************
;* ICA *
;*************************************************************

Seamless=Yes

;


;- ICA Session 1 –
;- Each line but the last must end with a ” –
;



CONNECT=ICA
Description=”XA65 Logon”
Icon=ica.bmp
HttpBrowsing=1
BrowserIP=http://WIserverFQDN
Application=”Desktop”
Fullscreen=1
Autoconnect=1
LocalCopy=No

The event log when running the above wnos.ini file shows:
ICA: Connecting to “XA65 Logon”
DNS/WINS can’t resolve [Desktop]
socket connect: Connection timed out
ICA[Desktop]: Connection timed out

I have also tried replacing the ICA configuration above with the following, as suggested in this thread, but this didn’t work either.

PnliteServer=http://FQDN of server ReconnectFromButton=2 Timeout=30 AutoConnectList=”FarmName:AppName”

The event log for this shows that it only gets as far as “Contacting SNTP”, like it doesn’t recognise the PnLiteServer command at all?

Any Suggestions?